Dräger PIR 7200
Reliable in the harshest industrial conditions – the infrared-optical transmitter Dräger PIR 7200 offers drift-free optics for continuous monitoring of carbon dioxide (CO2).
Product benefits
- Exceptional signal stability
- Based on patented innovations, the Dräger PIR 7200 combines maximum light-efficient optics with a signal-stabilizing 4 beam technology. The double-compensating construction is characterized by the greatest possible robustness towards interferences (e.g. dust and dirt deposits). Due to its non-imaging nature, the measuring signal of the Dräger PIR 7200 remains unaffected by a partially covered beam. It can thus be ensured that the instrument fully complies with the requirement "no false alarms".
- Fast response mode
- The sooner a measurable gas concentration is indicated, the faster counter measures can be initiated. The configurable response mode of the Dräger PIR 7200 can be set to "fast" for this purpose. In this mode, each measurable gas concentration is indicated within one second. In conjunction with low alarm thresholds, the gas transmitter can contribute to significantly reducing reaction times in the case of an emergency.
- Maximum reliability – SIL 2 certified!
- The Dräger PIR 7000 was developed and produced in accordance with SIL standards EN 61508 and EN 50402. For the first time ever, the software of a gas detection device was also assessed – excellent parameters and a SIL 2 certificate from the German TÜV certify the high product quality and reliability of the Dräger PIR 7000: Only two percent of a SIL 2 budget are utilized by the Dräger PIR 7000. Therefore, there is still much flexibility in the selection of control system and actuators. The Dräger PIR 7000 therefore not only meets the SIL 2 requirements but far surpasses them.
- Multiple configuration capabilities
- The standard parameterization of the Dräger PIR 7200 is based on many years of experience. Nonetheless, the device provides the option of setting many parameters specifically for customers and applications. A smaller or bigger measuring range as well as configurable special signals (for fault, beam block warning and maintenance) provide a wide area of utilization.
- Performance features
-
- Double-compensating and non-imaging optics (with 4-beam technology)
- Linearized measured value output for carbon dioxide
- Configurable measuring range in %(v/v) and ppm
- Analog 4 to 20 mA and digital HART® output signal (including HART multidrop mode)
- Beam block warning signal in the case of contaminated optics for predictive maintenance
- Multiple configuration capabilities of all special signals (in accordance with NAMUR NE 43)
- Specified minimum supply voltage of 13 V DC
- Extended specified temperature range from - 40 °C to + 77 °C / - 40 °C to + 170 °F
- Unrestricted usage in humid atmospheres
- Hermetically close enclosure made of stainless steel SS 316L
- Long maintenance interval thanks to minimum long-term drift
- Shock and vibration resistance up to an acceleration of 4 G
- No moving parts
- Typical life time: 15 years
- Ex approvals for worldwide use: ATEX, IECEx, UL, CSA
- Dust ex approval for zone 21 and 22
- Ingress Protection: IP 65, IP 66 and IP 67
- Continuous self-diagnosis in accordance with IEC/EN 61508
- Development and production in accordance with SIL guidelines as well as SIL 2 certification by the German TÜV (in accordance with IEC 61508)
Product Information
Accessories

Mounting set
Mounting the transmitter on flat or curved surfaces, vibration-resistant up to 4 G, flexibly mountable in any 90° direction.
Order No.: 68 11 648
Duct mount set
Mounting the transmitter directly in the pipes, air-tight even under positive pressure, optional accessory parts for functional checks and remote calibration available.
Order No.: 68 11 850

Splash guard
Guards the measuring cuvette against dirt and dust, quick gas exchange through ""chimney effect"", reflecting fluorescent strips.
Order No.: 68 11 912

Insect guard
Guards against insects or spiders that might block the gas inlet or outlet apertures of the splash guard, UV resistant.
Order No.: 68 11 609

Hydrophobic filter
Guards the measuring cuvette against dirt and dust, can be combined with other accessory parts.
Order No.: 68 11 890

Calibration adapter
Calibrating a transmitter (with mounted splash guard), up to wind force 10 Bft, mountable with one hand.
Order No.: 68 11 610

Status indicator
The permanent display of the measuring mode or disruption with a green or yellow light signal, can be combined with other accessory parts.
Order No.: 68 11 920

Flow cell
Function test/calibration of the transmitter during high wind forces and/or high test gas concentration, including status display, suitable for process applications.
Order No.: 68 11 910

Remote test adapter
Function test/calibration of the transmitter with the usual test gas concentrations, including status display.
Order No.: 68 11 930

Process adapter
Sampling or process applications, fast response behavior through minimum inner volume, material: POM (conductible).
Order No.: 68 11 915

Magnetic wand
Simple and fast calibration (zero-point and sensitivity) of the transmitter, feedback through status lights.
Order No.: 45 43 428

Dräger CC-Vision GDS
Configuration and calibration software for the following stationary gas detection systems: Dräger PIR 7000, Dräger PIR 7200, Dräger Polytron 7000, including status and diagnosis functions.
Order No.: 68 11 989
System Components
Tried and tested thousands of times and infinitely flexible. The modular Regard control system can be individually adapted to any monitoring task.
The Regard 3900 is a standalone, autonomous control system for up to 16 measuring channels. It is fully configurable and monitors the concentration of toxic gases, oxygen and combustible gases and vapors.
Robust and reliable. The compact Regard-1 single channel control system monitors the concentration of toxic gases, oxygen, combustible gases and vapors.
Related Products
The best performance characteristics alongside the greatest flexibility – the gas library of the infrared-optical transmitter Dräger PIR 7000 can be freely configured and offers exceptional linearity for each library substance across the whole measuring range.
Continuous measurement: The gas detector Dräger Polytron IR CO2 monitors the carbon dioxide concentration in the ambient air.
Modular design – highly flexible: The universal transmitter Dräger Polytron 7000 measures toxic gases and oxygen and can be optimally adjusted to the most different applications.
The Dräger Polytron 2 XP Tox is an explosion proof gas detector for continuous monitoring of toxic gases and Oxygen in ambient air. The transmitter converts the signal from an electrochemical sensor to a 4 to 20 mA analog or HART® or RS 485 digital signal output. The unit is designed for one-man calibration, and offers a variety of diagnostics and self test features.
Literature
List of detectable gases and vapours.
For over 70 years, Dräger has been one of the technology leaders in gas detection.
Safety Instrumented Systems are used to reduce the risk for the protection of people, plants, and environment.
Explosion hazards mostly arise from flammable gases and vapours. Instead of avoiding their ignition by explosion protection measures it may be preferable to detect them before they become ignitable.
Downloads
Many different diagnosis and configuration options from the master display
Integration with the Emerson's AMS®-Suite for diagnosis and configuration
Slots follow
Web site search
Contact Us
Dräger Safety Customer Support
Dräger Safety Customer Support
1-800-858-1737
1-800-922-5519
Contact form