Dräger REGARD control system
Tried and tested thousands of times and infinitely flexible. The modular Regard control system can be individually adapted to any monitoring task.
Product benefits
- Simple configuration
- The modular construction of the Regard system ensures a clear system structure. A configuration software allows a simple and safe configuration via PC or laptop as well as a reliable documentation of even complex systems.
- Established system
- The Regard product family includes single-channel and multi-channel cards, input and relay modules for mounting on DIN rails and communication cards and communication modules for linking with a PC or higher-ranking systems. There is the option to connect 4-20-mA transmitters, HART transmitters that communicate digitally and Polytron-SE-Ex sensing heads. The LEDs on the front plate of the cards provide information on alarm status and failure status. A display will show the current measured value. Measured values and alarm status can be transferred to linked systems via Modbus or Profibus. With more than 240,000 Regard inputs/outputs worldwide it is a well established system.
- Flexible systems
-
Regard control systems are flexible and can be adjusted to individual requirements. Conventional single-channel card systems are possible as well as multi-channel systems with markedly reduced installation costs.
The visualization of measured values and alarm states on a PC with the information transfer via Modbus can also be realized, as well as the integration in process control systems via the Profibus module.
Product Information
System Components
The best performance characteristics alongside the greatest flexibility – the gas library of the infrared-optical transmitter Dräger PIR 7000 can be freely configured and offers exceptional linearity for each library substance across the whole measuring range.
Modular design – highly flexible: The universal transmitter Dräger Polytron 7000 measures toxic gases and oxygen and can be optimally adjusted to the most different applications.
All in one enclosure: The Dräger Polytron 7500 is a pyrolyzer for the continual monitoring of toxic gases and halogenated carbons in the ambient air. The device contains all necessary functions such as sampling, processing and analysis.
Flame detection on the basis of a live video signal. Using a color video signal, the Dräger Flame 5000 detects characteristic properties of flames by means of its digital signal processing and software algorithmics. The Dräger Flame 5000 is approved for use in explosion-hazard areas according to ATEX, IECEx and FM/CFM.
Highly developed technology in Open-Path gas detection – the Dräger Polytron Pulsar 2 is intended for the detection of a range of gaseous hydrocarbons. This includes the alcane series from methane to hexane, propylene, ethylene, methanole and ethanole. Equipped with either a terminal box or a certified cable entry point, the detector can be very flexibly installed.
The Dräger Polytron 2 XP Ex is an explosion proof gas detector for continuous monitoring of combustible gases and vapours in ambient air.
The Dräger Polytron 2 XP Tox is an explosion proof gas detector for continuous monitoring of toxic gases and Oxygen in ambient air. The transmitter converts the signal from an electrochemical sensor to a 4 to 20 mA analog or HART® or RS 485 digital signal output. The unit is designed for one-man calibration, and offers a variety of diagnostics and self test features.
Related Products
The Regard 3900 is a standalone, autonomous control system for up to 16 measuring channels. It is fully configurable and monitors the concentration of toxic gases, oxygen and combustible gases and vapors.
Robust and reliable. The compact Regard-1 single channel control system monitors the concentration of toxic gases, oxygen, combustible gases and vapors.
Security at a glance. The QuadGard control unit can be configured for four different transmitters. Whether it is indoors or outdoors – the flat enclosure is easy to mount on the wall. To set the alarm, individual and group alarm outputs are available.
Downloads
This upgrade allows every user of the REGARD configuration software 1.0.0 and 1.1.0 to install some additional functions to the software. Version 1.2.0 is fully backwards compatible and has no influence to existing user settings within the configuration software.
Literature
List of detectable gases and vapours.
For over 70 years, Dräger has been one of the technology leaders in gas detection.
When there’s danger in the air ... this can quickly pose a high risk to humans, the environment, and all types of property and systems. Recognize the threat before it is too late.
Safety Instrumented Systems are used to reduce the risk for the protection of people, plants, and environment.
Explosion hazards mostly arise from flammable gases and vapours. Instead of avoiding their ignition by explosion protection measures it may be preferable to detect them before they become ignitable.