Dräger PSS® 100
Designed for the professional fire-fighter the Dräger PSS®100 features an advanced ergonomical backplate design providing outstanding comfort for the user. The Dräger PSS®100 can be used with either standard gauge or the DragerMan Bodyguard II - an innovative, fully electronic monitoring unit combining a host of monitoring and warning devices into a single instrument.
Product benefits
- Ergonomic Carrying System
- The advanced ergonomic design of the carrying system features a 3-point height adjustment allowing quick and easy adjustment to fit the torso length of any firefighter. This in combination with the unique sliding and pivoting waistbelt provides unrestricted movement and maximum comfort.
- Robust Hard Wearing Design
- Designed to endure the harshest of environments, every component is manufactured to a high degree of chemical, heat and flame resistance. Dräger PSS® 100 is fully designed and tested to comply with the highest flame engulfment standards in the world. The anti-static composite backplate,incorporates moulded carrying handles and is both flexible & impact resistant without compromising wearing comfort.
- Easy Donning and Doffing
- The Dräger PSS®100 features pull forward waistbelt adjustment and optional stainless steel friction buckles for quick and easy donning and doffing.
- Wide Range of Set Configurations
- The Dräger PSS®100 can be used with either standard gauge or the DrägerMan Bodyguard® II - which provides for an innovative, fully electronic monitoring unit combining a host of monitoring and warning devices into a single instrument. The set accepts a wide range of cylinder sizes including twin cylinder configurations and a host of additional performance enhancing accessories.
System Components
The Panorama Nova full-face mask has been successful in the market worldwide for decades and provides reliable and secure protection. In combination with a compressed air breathing apparatus or rebreather it is used as a tried and tested face piece by firefighters and in mining.

Dräger PSS® Lung Demand Valves
The compact lightweight design is easy to use and service. The robust impact-resistant design is achieved using an advanced composite housing in combination with a silicone rubber cover. The PSS range of LDVs is available with a range of facepiece connectors for different Dräger face masks.

Compressed-Air Cylinders
Choose from a broad range of compressed-air cylinders to configure the breathing apparatus to your individual requirements. Dräger offers a complete range of 200 bar and 300 bar steel and composite cylinders. Sizes range from 4L 200bar to 9L 300 bar with a choice of cylinder valves.
Accessories

Dräger FPS® 7000 Head Up Display (HUD)
The new Draeger FPS 7000 Head-Up-Display developed for use with the FPS 7000 facemask is an optional feature which easily integrates into the Draeger PSS 100 breathing apparatus (FPS 7000 HUD transmitter kitPSS 90/100 requiredfor operation) . Always within the field of view so that cylinder contents can be monitored without any manual action on the part of the user. The wireless design allows for ease of operation and being internal to the mask the HUD is protected from the ambient atmosphere.
Dräger FPS® 7000 HUD Transmitter Kit Dräger PSS® 90/100
Transmitter kit when fitted to the PSS 90 allows set to be used with FPS 7000 facemask with head-up-display. The transmitter provides wireless transmission of pressure signal the to the in-mask display.
Secondary Supply Hoses
A choice of secondary supply hose allows configuartion of the Draeger PSS 7000 for rescue and or decontamination applications.
- Secondary Supply Hose QRC -male, Secondary Supply Hose QRC - female Airline Belt Manifold
T-piece (2x 6.8 L 300 bar carbon composite cylinders)
Required to assemble twin cylinder SCBA configurations. Requires SCBA with universal cylinder strap
Inverted Y-Piece ( 2x 4 L 200 bar cylinders)
Breathing Apparatus Set Hard Shell Carrying Case
Breathing Apparatus Holdall Carrying Bag
Cylinder Covers
For additional cylinder protection choose from a range of cylinder covers available in different sizes.
Related Products
Dräger PSS® Merlin provides accountability and safety of BA wearers by relaying life saving information regarding air remaining and personal safety to the Entry Control point.

Dräger PSS® Rescue Hood
The Dräger PSS® Rescue Hood is intended for use only in conjunction with self contained compressed air breathing apparatus (SCBA), fitted with an appropriate secondary supply hose, and that is approved to the requirements of EN137. When the hood is placed over the head of an injured or distressed individual who is to be rescued, the hose connection to the secondary supply hose of the SCBA provides the individual being rescued with a regulated constant flow of breathable air into the hood from the SCBA.

Dräger RPS 3500 (Rescue Pack System)
Designed for use by first responder rapid intervention teams, allowing fire fighters to supply air to trapped colleagues or members of the public in hazardous atmospheres.
Service

When working in hazardous environments, it is essential that reliable protective equipment is available at all times.Dräger has developed a series of application-specific test units. They support your service technicians and ensure that users always have fully functional respiratory protective equipment ready for use.
Slots follow
Web site search
Get in contact with us
Dräger Safety Canada Ltd.
7555 Danbro Crescent Mississauga
L5N 6P9 Ontario
1-877-372-4371
1-905 821 2565
Contact form- Information materials
-

